75% OFF - SHORT TIME ONLY

en

UPS power supply: A UPS power supply in a server cabinet bridges power cuts and voltage dips so servers keep running or shut down safely without losing data.

More than 170,000 power interruptions are reported to Germany's Federal Network Agency (Bundesnetzagentur) each year by grid operators — and that figure only counts outages longer than three minutes. The short interruptions lasting seconds or milliseconds, often the most dangerous for sensitive IT hardware, don't even show up in that statistic.

A UPS (uninterruptible power supply) system catches exactly these outages and dangerous voltage spikes before they reach servers, routers, or switches and cause damage. Lehmann IT offers a wide power range for this — from compact single-phase systems starting at 1 kVA to three-phase systems reaching into the multi-MVA range, drawn from series like WISUS, CONVERT, or the WP series. All systems are built for high energy efficiency, scalability, and redundancy, combined with a compact footprint and high power density.

The right UPS solution suits IT departments and data center operators as much as industrial environments and critical applications with high operational-reliability requirements. Lehmann IT supports you across the entire lifecycle of the system — from initial concept through installation and operation to eventual decommissioning. For individual consultation on the right UPS configuration, contact Lehmann IT.

At a glance

UPS systems at a glance

The key features. Hover over a card.

Power1 kVA to MVA
Phasessingle- and three-phase
DesignMonoblock · modular
InstallationFloor-standing or rack
Redundancyn+1
AccessoriesBypass · Network · Battery
Vertical power strip with green digital display in a dark server cabinet

PDUs and power strips

Distributing and measuring power in the rack: PDUs for server cabinets and data centers.

Black sensor with two network ports for temperature and humidity

Rack Monitoring

Monitoring temperature, humidity and access in the cabinet: Rack monitoring systems.

Questions about UPS power supply

What does a UPS power supply do?

An uninterruptible power supply keeps IT running when the mains fails or the voltage drops. Its batteries bridge the gap until power returns, a generator starts, or the systems have shut down in an orderly way.

How big does the UPS need to be?

The output must cover the power of all connected devices, and the battery capacity sets the runtime. Lehmann IT offers modular UPS systems that can grow with the installation.

Where is the UPS installed?

Small and medium systems fit as 19-inch units in the server cabinet; larger ones stand next to the racks. Power is distributed through PDUs.

How do I know the UPS is working?

Status and battery condition can be watched with rack monitoring and regular tests.

Planning checklist: UPS power supply

  • Load: add up the power of all devices that must keep running.
  • Runtime: decide how long systems must bridge an outage.
  • Shutdown: plan automatic, orderly shutdown of servers.
  • Growth: choose a modular system if the load will grow.
  • Heat: include the UPS heat in the cooling plan.
  • Maintenance: plan battery checks and replacement intervals.

UPS systems in the Lehmann IT shop

Lehmann IT supplies modular UPS systems and accessories for server cabinets and data centers. See every model and option in the shop.

View UPS systems

Get in Touch With Us

Tell us what the IT has to do and where the cabinet will stand. We work out the cooling capacity, the noise level and the protection class with you, free of charge. Lehmann IT has designed and built server cabinets in its own production in Salach, Germany, since 1983, as a standard product or made to measure.

Contact us

Lehmann GmbH
Im Alber 10
D-73084 Salach

Follow Us

Follow us and never miss any news again.

Copyright 2026. Alle Rechte vorbehalten.
You are using an outdated browser. The website may not be displayed correctly.