Integrated cooling: how the built-in unit, guided airflow and sealing keep IT at a stable temperature, even in small rooms.

 

Modern IT systems generate considerable heat, especially in compact environments with high computing density. To ensure stable operation and prevent overheating, Lehmann GmbH develops server cabinets with integrated cooling systems that maintain optimal temperatures even under continuous load.

These cooling solutions are designed for industrial environments, data centers, and technical rooms where ambient conditions fluctuate or where standard ventilation is insufficient. The cabinets combine precise airflow management with energy-efficient cooling modules, ensuring reliable performance and extended hardware life.

Depending on the application, different cooling concepts are available. Cabinets with side cooling units or roof-mounted modules provide direct airflow to the installed equipment, preventing thermal hotspots. The CoolRack DX system uses inverter technology for precise temperature control, while the RearCool water-cooled cabinet offers high-capacity cooling for blade servers and clustered systems. For data centers, the FrontCooler enables efficient cold-aisle and hot-aisle configurations.

Inside the enclosure, airflow is guided through defined channels to maintain a stable microclimate. Thermostat-controlled fans activate only when required, reducing energy consumption and noise. Cable entry points and sealing elements ensure that cooling efficiency is maintained throughout the system.

All cooling solutions are engineered and manufactured in Germany at Lehmann GmbH, Im Alber 10, 73084 Salach. They combine durability, precision, and long service life. Customized configurations are available to match specific technical or environmental requirements, including airflow direction, cooling capacity, and integration with existing infrastructure.

The result is a reliable and efficient cooling system that protects valuable IT hardware, minimizes downtime, and ensures consistent performance in demanding industrial and technical environments.

 

At a glance

Which cooling for which heat load?

The heat load in the cabinet is roughly the power draw of all the devices in it. Hover over a bar or click it.

Passive ventilation1 kW
Compact all-in-one1 to 4 kWCoolRack Silent5 kWDX cabinets14 kWCW cabinets35 kWCoolRow / InRow55 kWPrecision cooling260 kW →

Scale 0 to 60 kW. Our recommendation: pick a little more cooling capacity than you need today, as reserve for new servers and hot summers.

CoolRack air-conditioned server cabinet

Small server room

For 1 to 4 kW a compact unit on the cabinet is enough, with a side or roof cooling module, and no separate air conditioning in the room. More on air-conditioned server cabinets.

Closed cold aisle containment in the data center

Cold aisle and hot aisle

Containment separates cold and warm air and raises efficiency in the data center. We plan it to match your racks: cold and hot aisle containment.

Questions about integrated cooling

When does a server cabinet need integrated cooling?

When the heat from the installed equipment can no longer leave the cabinet through vents or fans, the inside temperature rises above the range the hardware is designed for. A cabinet with integrated cooling removes that heat actively and keeps the inlet temperature stable, also in rooms without air conditioning.

How is the cooling capacity sized?

It must cover the electrical power of all devices in the cabinet, plus a reserve for growth and hot summer days. The guide Cooling a Data Center shows the calculation step by step.

Which cooling options are there?

Small loads can be handled with fans and PWM control. Higher loads need cabinets with built-in DX cooling, water cooling or roof-mounted units.

Why does sealing matter?

Cooled air should only flow through the equipment. Blanking panels, brush strips and closed doors stop warm exhaust air from mixing with the cool supply air, so the cooling works with less energy.

Can cooling be combined with soundproofing?

Yes. Cooling units and acoustic linings can be combined, so IT stays cool and quiet in offices and practices. See soundproof server cabinets.

Planning checklist: integrated cooling

  • Heat load: add up the power of every device in the cabinet and plan a reserve of around 20 to 30 percent.
  • Room conditions: note the warmest room temperature in summer, because the cooling unit releases its heat into that room.
  • Sealing: fit blanking panels in empty rack units and seal cable entries.
  • Power supply: plan a separate circuit for the cooling unit.
  • Monitoring: add a temperature sensor with an alarm, see rack monitoring.
  • Service access: leave room around the cabinet for maintenance and filter changes.

Air-conditioned server cabinets in the Lehmann IT shop

Lehmann IT builds air-conditioned server cabinets with 1 to 55 kW cooling capacity in Salach, Germany. See every model and option in the shop.

View air-conditioned cabinets

Get in Touch With Us

Tell us what the IT has to do and where the cabinet will stand. We work out the cooling capacity, the noise level and the protection class with you, free of charge. Lehmann IT has designed and built server cabinets in its own production in Salach, Germany, since 1983, as a standard product or made to measure.

Contact us

Lehmann GmbH
Im Alber 10
D-73084 Salach

Follow Us

Follow us and never miss any news again.

Copyright 2026. Alle Rechte vorbehalten.
You are using an outdated browser. The website may not be displayed correctly.